Industry Specific Inverter
Goodrive300 EPS Series Emergency Power Supply Inverter
  • Goodrive300 EPS Series Emergency Power Supply Inverter
Goodrive300 EPS Series Emergency Power Supply Inverter

Goodrive300 EPS inverter is developed based on the hardware platform of INVT high-performance vector inverter Goodrive300. It is equipped with mains synchronization function and widely applied in EPS power, shore power, fire emergency power and the power system of public facilities in subway, airport, hospital and large shopping mall.

Inquiry
  • Features
  • Specification parameter
  • Classic case
  • Data download
  • l Mains synchronous phase lock control

    Track and detect the input voltage via mains synchronous terminal card to keep the output voltage constant with that of the grid. The positive/negative sequence of inverter input power can be checked via function codes.

     

     Phase lock control wave

     

     Output phase shift control

    Auto compensation of phase shift caused by transformer can be made through detecting voltage phase of transformer output port or through setting compensation angle manually via function codes;

     Output voltage closed loop feedback control

    Perform closed loop feedback control on EPS output voltage to improve control precision of output voltage;

     V/F separation control

    Can realize V/F separation control to change V/F characteristic curve;

     Fast output

    The output frequency can accelerate to the given frequency in an instant;

     Drive various motors

    Drive various motors including permanent magnet synchronous motor, high speed spindle motor, direct drive motor and asynchronous motor.

     

     

  • Specification

    Indicator

    Power input

    Rated input voltage (V)

    Allowed AC operating voltage input range: 3PH 380V (-15%)~440V (+10%), voltage imbalance rate<3%;

    Support DC input

    Rated input current (A)

    See rated parameters

    Rated input frequency (Hz)

    50Hz or 60Hz, allowed range: 47~63Hz

    Rated input efficiency (%)

    ≥93%

    Power output

    Rated output voltage (V)

    Equal to input voltage with less than 5% error

    Rated output current (A)

    See rated parameters

    Rated output power (kW)

    See rated parameters

    Rated output frequency (Hz)

    50Hz/60Hz, fluctuation range: <±0.5%

    Operation control performance

    Control mode

    V/F, open loop vector, V/F separation

    Phase lock mode

    Open loop phase lock mode, closed loop phase lock mode

    Carrier frequency

    1.0~15.0kHz

    The carrier frequency has been properly adjusted in the factory, and users do not need to modify this parameter under normal conditions. If the frequency used by the user exceed the default value, derate by 20% for every additional 1kHz

    Auto reset at inverter fault

    Support auto reset of fault, the auto reset times and auto reset interval are both settable

    Protection function

    Motor overload protection

    Set by software function code

    Inverter overload protection

     G type: 1m at 150% of rated current, 10s at 180% of rated current, 1s at 200% of rated current

    P type: 1m at 120% of rated current

    Overvoltage protection

    DC bus 800V overvoltage

    Undervoltage protection

    DC bus 350V undervoltage (the 1st undervoltage point), support undervoltage pre-alarm output (relay terminal output)

    I/O phase loss protection

    Inverter main circuit I/O phase loss protection (optional)

    Phase detection protection

    Mains synchronous card detection signal, input phase loss (UIPL), output phase loss (UoPL), input sequence reversal (UIPE), Output sequence reversal (UoPE)

    Terminal function

    Analog input

    One 0~10V or 0~20mA input

    Analog output

    One 0~10V or 0~20mA output

    Digital input

    Six normal inputs, min frequency is 1kHz, max frequency is 50kHz

    Relay output

    Two programmable relay outputs (phase lock success signal output)

    Mains detection input

    R, S and T phases, detection mains phase and instantaneous value of line voltage

    Output voltage feedback

     

    U, V and W phases, output voltage value feedback, detect feedback voltage phase

    Others

    Installation mode

    Support wall-type, ground-type and flange-type installation

    Ambient temp

    -10~50, derate if the temp is above 40

    Protection level

    IP20

    Sine filter

    The optional sine filter is for satisfying lighting load